1 / 1
The flexible ULT system insulation system does not need to install a moisture barrier. Due to the unique closed cell structure and polymer blend formulation, LT low temperature elastomeric material has been highly resistant to water vapor permeation.
| Property | Base material | Test Method | |
|---|---|---|---|
| ULT System | LT System | ||
| Thermal Conductivity | -100°C, 0.028 -165°C, 0.021 |
0°C, 0.033 -50°C, 0.028 |
ASTM C177 |
| Density Range | 60-80Kg/m³ | 40-60Kg/m³ | ASTM D1622 |
| Recommend Operation Temperature | -200°C to 125°C | -50°C to 105°C | — |
| Percentage Of Close Areas | >95% | >95% | ASTM D2856 |
| Moisture Performance Factor | NA | <1.96x10⁻¹¹g/(m.s.Pa) | ASTM E 96 |
| Wet resistance Factor | NA | >10000 | EN12086 EN13469 |
| Water Vapor Permeability Coefficient | NA | 0.0039g/h.m² (25mm thickness) | ASTM E 96 |
| PH | ≥8.0 | ≥8.0 | ASTM C871 |
| Tensile Strength Mpa | -100°C, 0.30 -165°C, 0.25 |
0°C, 0.15 -50°C, 0.218 |
ASTM D1623 |
| Compressive Strength Mpa | -100°C, ≤0.3 | -40°C, ≤0.16 | ASTM D1621 |
| Inches | mm | Size (L * W) | ㎡ / Roll |
|---|---|---|---|
| 3/4" | 20 | 10 × 1 | 10 |
| 1" | 25 | 8 × 1 | 8 |