China Elastomeric Insulation For Ultra Low Temperature Pipeline Manufacturers, Supplier

When the operating temperature of the pipeline is lower than -180℃,consideration should be given to laying the vapor layer on the ULT of the ultra-low temperature adiabatic system to prevent liquid oxygen from forming on the metal pipe wall.

Product Description

The flexible ULT system insulation system does not need to install a moisture barrier. Due to the unique closed cell structure and polymer blend formulation, LT low temperature elastomeric material has been highly resistant to water vapor permeation.

System Technical Properties

Property Base material Test Method
ULT System LT System
Thermal Conductivity -100°C, 0.028
-165°C, 0.021
0°C, 0.033
-50°C, 0.028
ASTM C177
Density Range 60-80Kg/m³ 40-60Kg/m³ ASTM D1622
Recommend Operation Temperature -200°C to 125°C -50°C to 105°C
Percentage Of Close Areas >95% >95% ASTM D2856
Moisture Performance Factor NA <1.96x10⁻¹¹g/(m.s.Pa) ASTM E 96
Wet resistance Factor NA >10000 EN12086
EN13469
Water Vapor Permeability Coefficient NA 0.0039g/h.m² (25mm thickness) ASTM E 96
PH ≥8.0 ≥8.0 ASTM C871
Tensile Strength Mpa -100°C, 0.30
-165°C, 0.25
0°C, 0.15
-50°C, 0.218
ASTM D1623
Compressive Strength Mpa -100°C, ≤0.3 -40°C, ≤0.16 ASTM D1621

Key Advantages & Features

  • Insulation that maintains its flexibility at very low temperatures down to -200℃ to 125℃.
  • Protects the risk of corrosion under insulation.
  • Low thermal conductivity.
  • Easy installation even for complex shapes.

Product Dimensions

Inches mm Size (L * W) ㎡ / Roll
3/4" 20 10 × 1 10
1" 25 8 × 1 8

Frequently Asked Questions

Q Does this insulation system require the installation of a moisture barrier?
No, the system does not need a moisture barrier. Thanks to its unique closed-cell structure and polymer blend formulation, the low-temperature elastomeric material is inherently highly resistant to water vapor permeation.
Q What is the recommended operating temperature range for the ULT and LT systems?
The recommended operating temperature range for the ULT system is from -200°C to 125°C. For the LT system, the recommended operating range is from -50°C to 105°C.
Q What are the thermal conductivity values of the ULT system at ultra-low temperatures?
The thermal conductivity of the ULT system is 0.028 W/(m·K) at -100°C and decreases to 0.021 W/(m·K) at -165°C, ensuring high thermal performance in cryogenic applications.
Q Does the system help protect against corrosion?
Yes, the elastomeric formulation is designed to minimize and protect against the risk of Corrosion Under Insulation (CUI), which is a common concern in piping and industrial applications.
Q What is the density range of these insulation materials?
The density of the ULT system ranges from 60 to 80 Kg/m³, while the LT system has a density range of 40 to 60 Kg/m³.
Q How flexible is the material for complex pipe shapes and configurations?
The insulation material is designed to maintain high flexibility even at extremely low temperatures down to -200°C. This allows for straightforward and efficient installation over complex shapes and fittings.