China Kingflex rubber foam insulation tube Manufacturers, Pricelist

Kingflex rubber foam insulation tube has better heat-preservation effectiveness than PE material. Because of its best heat insulation property, they are widely used in chilled-water pipes, water pipes, air ducts of family air-conditioner, house-use fission air-conditioning and its joint pipes; side board, cover and bottom board and back board; hot-water pipes of building inner fitment, etc.
  • nominal wall thicknesses of 1/4”, 3/8″, 1/2″, 3/4″,1″, 1-1/4”, 1-1/2″ and 2” (6, 9, 13, 19, 25 , 32, 40 and 50mm)
  • Standard Length with 6ft (1.83m) or 6.2ft(2m).

Product Description

Technical Data
Property Unit Value Test Method
Temperature range °C (-50 - 110) GB/T 17794-1999
Density range Kg/m³ 45-65Kg/m³ ASTM D1667
Water vapor permeability Kg/(m.s.pa) ≤0.91×10⁻¹³ DIN 52 615 / BS 4370 Part 2 1973
μ - ≥10000 -
Thermal Conductivity W/(m.k) ≤0.030 (-20°C)
≤0.032 (0°C)
≤0.036 (40°C)
ASTM C 518
Fire Rating - Class 0 & Class 1 BS 476 Part 6 & Part 7
Flame Spread and Smoke Developed Index - 25/50 ASTM E 84
Oxygen Index - ≥36 GB/T 2406, ISO4589
Water Absorption, % by Volume % 20% ASTM C 209
Dimension Stability - ≤5 ASTM C534
Fungi resistance - Good ASTM 21
Ozone resistance - Good GB/T 7762-1987
Resistance to U.V. and weather - Good ASTM G23
Features Overview
  • Excellent fire-resistance performance & Sound absorption.
  • Low thermal conductivity (K-Value).
  • Good moisture resistance.
  • Environmentally friendly.
  • Easy to install & Nice appearance.
  • Closed-cell structure provides excellent condensation and energy-loss control
  • Effectively retards degradation due to ultraviolet (UV) radiation
  • Flexible material with dusted, relaxed ID’s for easy installation
  • Superior toughness to withstand on-site handling
  • Built-in vapor barrier eliminates need for additional vapor retarder
  • Complete size range for HVAC/R
  • Distinguish between different pipelines
Application Details
Frequently Asked Questions
What is the operating temperature range for this insulation material?
This insulation material is designed to operate efficiently within a temperature range of -50°C to 110°C, making it highly versatile for various thermal applications.
How does the closed-cell structure benefit condensation control?
The closed-cell structure inherently resists moisture penetration, achieving a built-in vapor barrier (water vapor permeability ≤0.91×10⁻¹³ Kg/(m.s.pa)). This effectively prevents condensation and controls energy loss without requiring additional vapor retarders.
What is the thermal conductivity rating of this product?
According to ASTM C 518 standards, the material has low thermal conductivity (K-Value) rates of ≤0.030 W/(m.k) at -20°C, ≤0.032 W/(m.k) at 0°C, and ≤0.036 W/(m.k) at 40°C.
Does this insulation material offer reliable fire resistance?
Yes, it achieves a Class 0 & Class 1 fire rating in compliance with BS 476 Part 6 & 7. Additionally, it has a Flame Spread and Smoke Developed Index of 25/50 under ASTM E 84.
Is the material resistant to environmental factors like UV and ozone?
Yes, the material exhibits excellent resistance to ozone (tested under GB/T 7762-1987), fungi (ASTM 21), and U.V. radiation & weathering (ASTM G23), ensuring long-term durability.