Application: Low temperature storage tank; industrial gas and agricultural chemical production plants; platform pipe; gas station; nitrogen plant...
| Property | Base material | Test Method | |
|---|---|---|---|
| Kingflex ULT | Kingflex LT | ||
| Thermal Conductivity | -100°C, 0.028 -165°C, 0.021 |
0°C, 0.033 -50°C, 0.028 |
ASTM C177 |
| Density Range | 60-80Kg/m³ | 40-60Kg/m³ | ASTM D1622 |
| Recommend Operation Temperature | -200°C to 125°C | -50°C to 105°C | - |
| Percentage Of Close Areas | >95% | >95% | ASTM D2856 |
| Moisture Performance Factor | NA | <1.96x10⁻¹¹ g/(m·s·Pa) | ASTM E 96 |
| Wet resistance Factor μ | NA | >10000 | EN12086 EN13469 |
| Water Vapor Permeability Coefficient | NA | 0.0039g/h.m² (25mm thickness) |
ASTM E 96 |
| PH | ≥8.0 | ≥8.0 | ASTM C871 |
| Tensile Strength Mpa | -100°C, 0.30 -165°C, 0.25 |
0°C, 0.15 -50°C, 0.218 |
ASTM D1623 |
| Compressive Strength Mpa | -100°C, ≤0.3 | -40°C, ≤0.16 | ASTM D1621 |
Insulation maintains excellent flexibility at extremely low temperatures down to -200℃ up to +125℃.
Significantly reduces the risk of crack development and propagation under thermal stress.
Reduces the risk of Corrosion Under Insulation (CUI) through superior moisture barrier properties.
Provides physical protection against mechanical impact, external vibration, and shock.
Outstanding low thermal conductivity ensures optimal thermal performance and energy savings.
| Dimension Roll Specifications | |||
|---|---|---|---|
| Inches | mm | Size (L × W) | ㎡ / Roll |
| 3/4" | 20 | 10 × 1 m | 10 |
| 1" | 25 | 8 × 1 m | 8 |
Kingflex ULT is optimized for extremely low temperatures, with a recommended range of -200°C to 125°C. Kingflex LT is suitable for temperature applications ranging from -50°C to 105°C.
These materials are widely applied in low temperature storage tanks, industrial gas and agricultural chemical production plants, platform piping, gas stations, and nitrogen plants.
By maintaining a high closed-cell structure (>95%) and superior wet resistance (wet resistance factor μ > 10000 for Kingflex LT), the materials keep moisture away from the metal surface, which drastically reduces the risk of corrosion under insulation.
The insulation is available in standard roll sizes: 3/4" (20mm thickness) at 10m x 1m (10㎡/roll), and 1" (25mm thickness) at 8m x 1m (8㎡/roll).
Under the ASTM C177 standard, Kingflex ULT exhibits low thermal conductivity, measuring 0.028 W/(m·K) at -100°C and dropping to 0.021 W/(m·K) at -165°C.