Kingflex flexible ultra low temperature adiabatic system has the inherent characteristics of impact resistance, and its cryogenic elastomer material can absorb the impact and vibration energy caused by the external machine to protect the system structure.
| Kingflex Dimension | |||
|---|---|---|---|
| Inches | mm | Size (L * W) | ㎡ / Roll |
| 3/4" | 20 | 10 × 1 | 10 |
| 1" | 25 | 8 × 1 | 8 |
Kingflex ULT insulation can be used in Low temperature storage tank; industrial gas and agricultural chemical production plants; platform pipe; gas station; nitrogen plant...
| Property | Base material | Standard / Test Method | |
|---|---|---|---|
| Kingflex ULT | Kingflex LT | ||
| Thermal Conductivity | -100°C, 0.028 -165°C, 0.021 |
0°C, 0.033 -50°C, 0.028 |
ASTM C177 |
| Density Range | 60-80Kg/m³ | 40-60Kg/m³ | ASTM D1622 |
| Recommend Operation Temperature | -200°C to 125°C | -50°C to 105°C | - |
| Percentage Of Close Areas | >95% | >95% | ASTM D2856 |
| Moisture Performance Factor | NA | <1.96x10⁻¹¹g(m.s.Pa) | ASTM E 96 |
| Wet resistance Factor (μ) | NA | >10000 | EN12086 / EN13469 |
| Water Vapor Permeability Coefficient | NA | 0.0039g/h.m² (25mm thickness) | ASTM E 96 |
| PH | ≥8.0 | ≥8.0 | ASTM C871 |
| Tensile Strength Mpa | -100°C, 0.30 -165°C, 0.25 |
0°C, 0.15 -50°C, 0.218 |
ASTM D1623 |
| Compressive Strength Mpa | -100°C, ≤0.3 | -40°C, ≤0.16 | ASTM D1621 |
With more than four decades of dedicated experience in manufacturing and applications, this insulation technology is riding on top of the wave.
Kingflex ULT insulation is specifically engineered for ultra-low temperature and cryogenic environments. Common installations include low-temperature storage tanks, industrial gas systems, agricultural chemical production plants, platform piping, gas stations, and nitrogen plants.
The recommended operating temperature range for Kingflex ULT is -200°C to 125°C. This makes it highly effective for liquid nitrogen, LNG, and other cryogenic applications.
The insulation system is built using high-performance cryogenic elastomer materials. This structural composition allows the insulation layer to absorb mechanical impact and vibration energy from external machinery, protecting the piping system integrity.
According to ASTM C177 testing standards, Kingflex ULT features a thermal conductivity of 0.028 W/(m·K) at -100°C and reaches as low as 0.021 W/(m·K) at -165°C, ensuring exceptional thermal efficiency.
Kingflex ULT features a closed-cell ratio of greater than 95% (tested under ASTM D2856). A high closed-cell count prevents moisture penetration and water vapor migration, maintaining long-term thermal insulation performance in sub-zero environments.